95B064930 | IS-65-C2-03 | Inductive Sensor, Ø6.5 Standard - Non Flush 2Mm - Pnp Nc - 2M Cable
Technical Specifications
SKU: 95B064930-datalogic
Nominal Sensing Distance
2 mm
Operating Distance
0 - 1.62 mm
Standard Target
8x8 mm FE360
Correction Factor
Copper: 0.4-0.5, Aluminium: 0.4-0.6, Brass: 0.5-0.7, Stainless Steel: 0.7-1.05
Hysteresis
< 10%
Application Description
D6.5 standard non-flush mount
Functions
Proximity
Output Type
PNP
Output Function
NC
Switching Frequency
1 kHz
Response Time
0.5 ms
Operating Voltage
10-30 Vdc
No-Load Supply Current
10 mA
Load Current
200 mA
Output Voltage Drop
1.2V @ 100mA
Maximum Ripple Content
10%
LED Indicators
Yellow LED output state
Time Delay Before Availability
50 ms
Short-Circuit Protection
Yes
Reverse Polarity Protection
Yes
Emission
‰¥ 100 kHz
Inductive Load Protection
Yes
Mounting
Unshielded
Dimensions
Ø 6.5 x 55 mm
Housing Material
Nickel-plated brass
Connection
2m PVC Cable
Active Head Material
LCP
Diameter
6.5 mm
Approvals
CE, cULus
Operating Temperature
-25°C to +70°C
IP Rating
IP67
Technical Documents
- Datalogic Basic Inductive Sensors Manual (PDF)
- Datalogic Basic Inductive Sensors Brochure (PDF)
- Datalogic Inductive Sensors Catalog (PDF)
- Datalogic Sensors Product Guide (PDF)
We are always wanting to provide more information! In need of a technical document? Let us know!