DL Series Ductless Fume Hood
The DL Series Ductless Fume Hood is an ergonomic and well designed addition to the lab environment. Rigorously tested against international standards, this model series comes in two sizes, and features options for different types of carbon filters, and a pre-filter to extend the life of the main filter.
One series, several modelsPick the model that fits your job.Models in this series differ in size, capacity or configuration. Browse them on this page, or call us and we'll match one to your application.Each model is sold and priced individually.
Details
Product information
Overview
Filtration Features
• Activated carbon filter works with extensive range of chemicals.
• Accessories and options for different absorbing grades (see DL Series Accessories)
• Select one of six filters.
• Mounted pre-filter extends main filter’s life span
Construction Features
• Internal wind speed in the workspace can be identified with attached anemometer. Wind speed can be controlled by identifying varying wind speed in accordance with surrounding environment and filter conditions.
• Connection with separate exhaust system is not required, since the hood already has recirculation air flow discharging into the laboratory.
• Filter of cartridge type can be easily replaced by opening the upper cover in the front of the unit.
• Front sash can be fully opened and fixed to enable experimental apparatus and equipment to move conveniently into the workspace.
• As a utility hole is provided, apparatus inside the hood can easily be connected to outside the hood or apparatus outside the hood can do so to inside the hood.
• As a blower of large enough capacity is adopted, sufficient intake flow rate is maintained and noise is low.
• A fluorescent light is provided outside the workspace so that air circulation is not hindered. Pollution from reagents can be minimized and intensity of illumination can be maintained.
•Various filters and work surface are optional for their experimental purposes. (Refer to accessory section)
Testing Standards
It is manufactured and rigorously tested against international standards. These include (1) Efficiency, Capacity of Activated carbon filters tested according to BS-7258-1:1994 (2) Structure, Electrical outlet, Lighting, Sound level tested according to BS 7989: 2001 (3) Local smoke, large volume visualization, face velocity, tracer gas tested according to ANSI/ASHRAE 110-1995, NF EN 14175-1
• Activated carbon filter works with extensive range of chemicals.
• Accessories and options for different absorbing grades (see DL Series Accessories)
• Select one of six filters.
• Mounted pre-filter extends main filter’s life span
Construction Features
• Internal wind speed in the workspace can be identified with attached anemometer. Wind speed can be controlled by identifying varying wind speed in accordance with surrounding environment and filter conditions.
• Connection with separate exhaust system is not required, since the hood already has recirculation air flow discharging into the laboratory.
• Filter of cartridge type can be easily replaced by opening the upper cover in the front of the unit.
• Front sash can be fully opened and fixed to enable experimental apparatus and equipment to move conveniently into the workspace.
• As a utility hole is provided, apparatus inside the hood can easily be connected to outside the hood or apparatus outside the hood can do so to inside the hood.
• As a blower of large enough capacity is adopted, sufficient intake flow rate is maintained and noise is low.
• A fluorescent light is provided outside the workspace so that air circulation is not hindered. Pollution from reagents can be minimized and intensity of illumination can be maintained.
•Various filters and work surface are optional for their experimental purposes. (Refer to accessory section)
Testing Standards
It is manufactured and rigorously tested against international standards. These include (1) Efficiency, Capacity of Activated carbon filters tested according to BS-7258-1:1994 (2) Structure, Electrical outlet, Lighting, Sound level tested according to BS 7989: 2001 (3) Local smoke, large volume visualization, face velocity, tracer gas tested according to ANSI/ASHRAE 110-1995, NF EN 14175-1
| Features & Benefits | |
|---|---|
| Air Flow Meter: Swing Vane Type | |
| Noise Level: 55dB at Normal Operation | |
| From $6,970 to $7,645 |