SG-BWS-T4-MT | Safety control unit pl=e double muting
S300-SG-ST safety sensors have been certified for integration with SG-BWS-T4 units, a Type 2 or Type 4 safety system (depending on the model used).
- Free UPS Ground over $999.99
- Factory-authorised service

Details
Product information
Overview
Datalogic SG-BWS-T4-MT / 957051010
Safety control unit pl=e double muting
S300-SG-ST safety sensors have been certified for integration with SG-BWS-T4 units, a Type 2 or Type 4 safety system (depending on the model used).
DEFOGGING models, with heated front glass, are ideal for applications where sudden changes of the temperature can cause condensation. When placed appropriately, they can be used in substitution of body protection safety light curtains, or to guard small size openings.
Features:
- Emitter-receiver photocells with test input on emitter
- Maximum operating range : 8 m for S300-SG-ST2; 50m for S300-SG-ST4
- Rectangular shape ( 25 mm x 85 mm x 70 mm) in plastic
- Effective aperture angle : ??2.5° for Type 4 models, ??5° for Type 2 models (IEC 61496-2)
- Emission: infrared LED
- M12 4-poles connectors
- Operating temperature: -40° - 55°C
Applications:
- Automatic machines
- Robots
- Automatic assembling lines
- Palletizers and Depalletizers
- Protecting perimeter areas
| Technical Specifications | |
|---|---|
| Nominal Sensing Distance | According to the sensors used: S5*ST* up to 8m; SL5*ST and S300*ST4 up to 40m; S300*ST2 up to 50m |
| Controlled Height | n/a |
| Sensitivity Adjustment | Dip-switch |
| Effective Aperture Angle | n/a |
| Application Function Principle | Control unit |
| Available Functions | Manual/Automatic Restart, EDM, Double Muting, Override |
| Description | DIN-rail mount case |
| Max. Number of Sensors Connected | 4 x S5*ST/SL5*ST/S300*ST pairs |
| Max. Number of Muting Sensors | 4 x PNP-NO |
| Functions | 4 safety light beam inputs - muting |
| Safety Type | Type 4 safety control unit (A/M) |
| SIL | 3 |
| SILCL | 3 |
| Performance Level (PL) | e |
| PFHd | 5,43E-09 |
| DCavg | 99,65% |
| MTTFd | 183 years |
| SFF | 98,80% |
| Output Type | 2 Relay NO |
| Response Time | 35 ms |
| Operating Voltage | 24 Vdc 15% |
| Emission | n/a |
| Interference to External Light | n/a |
| Power Consumption - Receiver | n/a |
| Power Consumption - Emitter | n/a |
| Cable Length (Power Supply/Output) | 50m |
| Cable Length (Sensors) | 50m |
| Power Consumption | 3,8W |
| Dimensions | 68x99x119 mm |
| Connections | Terminal block |
| Storage Temperature | -25 to +70°C |
| Material | Plastic - PA66 |
| Vibrations | Width 0.35 mm, frequency 10 to 55Hz; 20 sweep per axis, 1octave/min (EN 60068-2-6) |
| Shocks | 16 ms (10 G) 1,000 shocks per axis (EN 60068-2-29) |
| Approvals | CE, TÜV |
| EMC Compatibility | According to 2014/30/EU Directive |
| Operating Temperature | 0 to +55°C |
| Mechanical Protection | IP20 |
| MPN | SG-BWS-T4-MT |